Gas Detection System TrueSafe Industrial Gas Leak Detector for Hydrogen
Gas Detection System TrueSafe Industrial Gas Leak Detector for Hydrogen

Gas Detection System TrueSafe Industrial Gas Leak Detector for Hydrogen

KTI0700800IGLD

Product Description: TS21I-CAT
Model TrueSafe TS21I-CAT gas detector is used to detect natural
gas, LPG, coal gas, alkane, combustible gas, and
gasoline, Alcohol, ketone, benzene etc., organic solvent as well
as Hydrogen gas. Application area of this detector is in
Automotive, Medical, Refineries and Petrochemical Plants, Oil
and Gas, LPG station, Chemical and Pharma Industries, Power
plants, Gas Boiler, and Spray-Paints etc where gas leakage is
possible. It reads the gas concentration in Air and transmits to a
detection panel over digital bus as well as it shows LEL level on
display. Catalytic type of gas sensor is used in this detector. This
sensor provides good reproducibility, good performance against
changes in atmospheric temperature and humidity. It has long
life-span and easy operation. Detector has provision to set Two
alarm levels of warnings (High & Low).
Relay output is provided and this output can be connected to the conventional Gas Detection Panel OR SCADA system.
For BMS connectivity detector has provided RS485 output. Additionally 4-20mA and Selectable 0-5 V & 0-10V Analog
output could be also available. Enclosure used is suitable for Zone 1 & Zone 2 hazardous areas.
Application:
 OIL & GAS refinery Industries
 Automotive and Power plants
 Refineries and Petrochemical Plants
 Medical Laboratories & Chemical storage room
 GAS pipe installation areas
 Chemical & Pharma Industry
 Steel Industries
Salient Features:
 Calibration required as per OISD / Safety Standards.
 Simulate alarm, fault and warning.
 Replaceable Sensor Provision.
 View gas reading, configuration and diagnostic.
 Wide Operating Temperature Range.
 Immune to Catalytic Poisons.
 Failsafe Operation.
Model: TrueSafe TS21I-CAT Specification
Operating Principle Catalytic Combustion(oxidation).
Measuring Range 0-100% LEL
Signal Output*** 4-20mA, HART over 4-20mA (Optional).
Modbus Output*** The Modbus output to enable connection to a multi-drop Modbus network.
Relay Output*** Provides NO/NC relay output.
Fault Alarms 0mA (General Fault), 2mA (Calibration), 20-21mA (Over Range).
Gas Sensor Catalytic Type (Replaceable) sensor
Response Time T90 < 10 to 30 seconds
Operation Temperature - 40°C to + 70°C
Humidity 0 to 95% RH
Drift over Year ± 2 % FSD
Power Supply 18 to 32V DC (24V DC)
Environmental Protection IP66 /67
Hazardous Classification Ex II 2 G Exd ia IIC T4 Gb
Zones Certified for use in Zone 1 & 2, and Zone 21 & 22 hazardous areas
Transmitter Material Enclosure Aluminum Alloy LM6, Flameproof Enclosure
Sensor Material Enclosure SS316
Weight Approx 1kg.
Dimensions 150 mm (L) x 145 mm (W) x 150mm (H) (varies with/without display option)
Display LED indication and Seven segment Display
Cable Entry M20 x 2 nos.
Safety Approvals ATEX, CCoE (PESO), BIS-CM/L – 3927980
Sensor Life 6 to 24 months
Transmitter Warranty 1 year

Gas Detection System TrueSafe Industrial Gas Leak Detector for Hydrogen

KTI0700800IGLD

Specifications for this item

  • Unit
  • HSN Code
  • Weight
  • Warranty
  • Tags/categories
Enter number of units to add to cart.
Usually dispatched within 21 days